126kV High-voltage AC Dead tank SF6 circuit breaker
  • 126kV High-voltage AC  Dead tank SF6 circuit breaker
Key attributes
Brand ROCKWILL
Model NO. 126kV High-voltage AC Dead tank SF6 circuit breaker
Rated voltage 126kV
Rated normal current 3150A
Rated frequency 50/60Hz
Series LW
Product descriptions from the supplier
Description

Description

Outdoor 126kV High-voltage AC  Dead tank SF6 circuit breaker is an outdoor - installed, three - pole, 50Hz AC high - voltage switching device that uses SF6 gas as the arc - extinguishing and insulating medium. It can be used to interrupt and close rated current and fault current, interrupt and close capacitor banks, transfer circuits, and also be used as a tie - circuit breaker to achieve the control and protection of power transmission and transformation lines and equipment. It is especially suitable for frequent operations. The circuit breaker is equipped with a spring operating mechanism.

Main Features

The material of the contact end is copper - tungsten alloy, which has strong arc - resistance ability. Especially during the opening and closing process of the circuit breaker, an arc will be generated, and a large amount of energy acts on the arcing contacts. Therefore, the ablation - resistant material is an important guarantee for the electrical life. The large and small nozzles are made of polytetrafluoroethylene material with excellent high - temperature and arc - resistance properties and appropriate fillers.

Technical specifications

 

Documentation Resource Library
Dead Tank Circuit Breakers Catalog
Restricted.
Dead Tank Circuit Breakers Catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: What are the structural characteristics of the tank circuit breaker?
A:

Integral Tank Structure:

  • Integral Tank Structure: The breaker's arc quenching chamber, insulating medium, and related components are sealed within a metal tank filled with an insulating gas (such as sulfur hexafluoride) or insulating oil. This forms a relatively independent and sealed space, effectively preventing external environmental factors from affecting the internal components. This design enhances the insulation performance and reliability of the equipment, making it suitable for various harsh outdoor environments.

Arc Quenching Chamber Layout:

  • Arc Quenching Chamber Layout: The arc quenching chamber is typically installed inside the tank. Its structure is designed to be compact, enabling efficient arc quenching within a limited space. Depending on different arc quenching principles and technologies, the specific construction of the arc quenching chamber may vary, but generally includes key components such as contacts, nozzles, and insulating materials. These components work together to ensure that the arc is quickly and effectively extinguished when the breaker interrupts the current.

Operating Mechanism:

  • Operating Mechanism: Common operating mechanisms include spring-operated mechanisms and hydraulic-operated mechanisms.

  • Spring-Operated Mechanism: This type of mechanism is simple in structure, highly reliable, and easy to maintain. It drives the opening and closing operations of the breaker through the energy storage and release of springs.

  • Hydraulic-Operated Mechanism: This mechanism offers advantages such as high output power and smooth operation, making it suitable for high-voltage and high-current class breakers.

Q: What are the leakage rate requirements for the arc quenching chamber of a tank-type circuit breaker?
A:

The leakage rate of SF₆ gas must be controlled at an extremely low level, typically not exceeding 1% per year. SF₆ gas is a potent greenhouse gas, with a greenhouse effect 23,900 times that of carbon dioxide. If a leak occurs, it can not only cause environmental pollution but also lead to a decrease in the gas pressure within the arc quenching chamber, affecting the performance and reliability of the circuit breaker.

To monitor the leakage of SF₆ gas, gas leakage detection devices are typically installed on tank-type circuit breakers. These devices help to promptly identify any leaks so that appropriate measures can be taken to address the issue.

Q: What are the requirements for monitoring the gas decomposition products of the SF6 tank circuit breaker?
A:

During the normal operation and interruption processes of a circuit breaker, SF₆ gas can decompose, producing various decomposition products such as SF₄, S₂F₂, SOF₂, HF, and SO₂. These decomposition products are often corrosive, toxic, or irritating, and therefore require monitoring.If the concentration of these decomposition products exceeds certain limits, it may indicate abnormal discharges or other faults within the arc quenching chamber. Timely maintenance and handling are necessary to prevent further damage to the equipment and to safeguard personnel health.

Related Products
Related Solutions
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
IEE Business
Source professional electrical partners, experts, and explore smart grid & energy solutions.