750kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation

  • 750kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation
Key attributes
Brand ROCKWILL
Model NO. 750kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation
Rated voltage 750kV
Rated frequency 50/60Hz
Rated capacity 500kVA
Series ODFPS
Product descriptions from the supplier
Description

Product Description:

The 750kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation is a critical component designed for the highest tiers of power transmission systems. Its robust oil-immersed cooling technology ensures stable thermal performance and long-term reliability under heavy loads. The unique three-winding configuration provides exceptional operational flexibility, enabling efficient power transfer and system interconnection. As a "no excitation" design, it offers superior reliability and simplified maintenance by eliminating the need for on-load tap-changing mechanisms, making it an ideal and dependable solution for ultra-high voltage (UHV) grid applications that demand unwavering performance.

Product Characteristics:

  • Optimized Structural Design: Utilizes advanced computational analysis of electrical, magnetic, mechanical, and thermal behavior to ensure robust and reliable construction.

  • Superior Electrical Performance: Complies with IEC standards while offering customized solutions, with partial discharge levels significantly lower than IEC 60076-3 limits.

  • Enhanced Operational Reliability: Multi-physics field analysis optimizes insulation, amp-turns balance, and cooling, delivering strong resilience to overvoltage and short-circuit events while eliminating risks of local overheating.

  • Premium Component Selection: Provides an exceptional user experience with a clean appearance, leak-free construction, and maintenance-free operation—no core disassembly required.

Technical Parameters

Among these, some autotransformers cover non-standard voltage levels including 121kV, 132kV, 138kV, 200kV, 225kV, 230kV, 245kV, 275kV, 330kV, 345kV, 400kV and 756kV,  We also provide customization services.

Rated capacity (kVA)

334

500

500

700

Voltage combination and tapping range

HV (kV)

765/√3

Tapping range(kV)

230/√3±2×2.5%

345/√3±2×2.5%

LV (kV)

63

Vector group

La0I0

No-load loss(kW)

95

110

125

130

On-load loss(kW)

570

860

860

1225

No-load current (%)

0.15

0.15

0.15

0.15

Short-circuit impedance (%)

HV-MV14

HV-LV50

MV-LV33

HV ~MV 

19 ~ 22

HV-LV46

MV-LV

23~24

HV-MV14

HV-LV50

MV-LV33

HV-MV18

HV-LV58

MV-LV36

Capacity assignment (MVA)

334/334/100

500/500/150

500/500/150

700/700/233

Note: Transformers with various special parameters and performance can be manufactured according to customer requirements.

Normal Service Conditions

(1) Altitude:  ≤1000m;

(2) Ambient temperature:Maximum temperature: +40℃;Maximum monthly average temperature: +30℃;Maximum yearly average temperature: +20℃;Minimum temperature: -25℃.

(3) Power supply: approximate sinusoidal wave, three-phase symmetrical approximately

(4) Installation site: indoor or outdoor, without the obvious contamination.Note: The transformer used in special conditions should be specified when ordered.

Introduction to Structure and Performance:

Core:

  • Adopting highest quality, non-aging, cold-rolled, grain-oriented, and high permeability silicon steel lamination silicon steel sheets.

  • Processed on the GEORG length-cutting line from Germany.

  • Fully mitred joint, step lapping and polyester tape binding structure making the transformer with low no-load losses and low noise level.

  • Placing vibration isolation pads between the body and the tank to reduce vibration that transmits to the tank.

Winding:

  • Winded by high-quality oxygen free copper with lower resistivity.

  • Processed and manufactured on horizontal winding machines and large CNC vertical winding machines from both radial and axial directions.

  • Reasonable transposition applied between paralleling wires, magnetic shielding used for guiding flux leakage when necessary to reduce the stray losses of the transformer.

  • Reasonable design of insulation structure improving the ability of withstanding overvoltage.

  • Optimizing the ampere turns distribution of the winding, increasing the radial support and axial compression of the winding, using the pre-densification of spacers, constant pressure drying, to resist the impulse current.

Tank:

  • Bell type or cover bolted type tank.

  • Carbon dioxide shielded welding process.

  • High-quality gaskets and the limit groove.

  • Strict leak detection test procedures.

Others:

  • Cold-weld connection technology leads to improve the cleanliness of active part.

  • The vacuum disassembly and the vacuum filling technology measures reduce the partial discharge level effectively and enhance the transformer operating reliability.

  • The structure of "Six Direction Positioning" between the active part and the tank assures that the transformer has a strong ability of anti-transportation impact or anti-earthquake.

  • Surface treatment and coating, fine processing to tank surface, 7 steps such as acid-washing and phosphating, etc. special anti-fouling paint, ensuring not falling off or rusting away.

 

FAQ
Q: How does the oil-immersed design of the 750kV Single-phase Autotransformer with Three Windings benefit its operation?
A:

The oil-immersed design uses insulating oil for two key functions: first, it provides excellent electrical insulation between windings and components; second, it acts as a cooling medium, dissipating heat generated during operation to ensure the transformer works within a safe temperature range, thus extending its service life.

Q: What is the significance of "no excitation" in the 750kV Single-phase Oil-Immersed Autotransformer with Three Windings and No Excitation?
A:

"No excitation" means the transformer can only adjust voltage when it is completely disconnected from the power grid (no load current). This design simplifies the structure, enhances reliability, and is suitable for scenarios where voltage regulation frequency is low and stable grid operation is prioritized.

Related Products
Related Solutions
Send inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO