What is the standard of Rockwill Auto Recloser?
Rockwill Auto Recloser is a flexible pole mounted outdoor vacuum switching device that can trip and reclose up for a temporary distribution line fault. It reduces the blackout time greatly and improves the stability of power grid operation. The operation status also can be controlled and monitored by mobile phone and SCADA system.
Rockwill standard auto recloser is fully meet the Standard IEC62271-111 & ANSI/IEEE C37.60. Fully follow the above standard for type test and routine test. Additional functions reuirement is offered, like: ESKOM standard, TANESCO standard, BPC standard, SEC standard, DEC, Meralco, KPLC, BREB, etc. Besides, Rockwill even provide with patent design for new recloser.
RCW+ Auto Recloser
RCW+ type auto recloser is ANSI/IEC standardized plus design products which is equipped with one magnetic actuator mechanism, one manual closing/opening/Locking device, 3 current sensors, max 6 voltage sensors, with more functional like protection curves + curves programble, coodination logics + logics programble, programble communication protocols(Modbus, DNP3.0, IEC 60870-5-101/104), PC software, APP control tool, etc.
RCW+ type auto circuit recloser is a solid insulation reclosure with zero pressure Sf6 GAS sealed. with high creepage design, higher insulation level, suit using for Maximum 42kV level sytem.
It's vacuum interrupting technology, and IP67 IP protection class, It avoid any bad influence high polution enviroment of humidity, salt or alkali incursion or small animal,etc...
● Main technical data of auto recloser
N | Item | Unit | Data | ||||
1 | Rated max voltage | kV | 12 | 15 | 27 | 38 | |
2 | Rated current | A | 630/800/1250 | ||||
3 | Rated frequency | HZ | 50/60 | ||||
4 | Power frequency 1min | Dry | kV | 45 | 55 | 65 | 95 |
Wet | 30 | 45 | 55 | 80 | |||
5 | Lightning impulse withstand voltage(peak) | kV | 75/95* | 95/100* | 125/150* | 170/200* | |
6 | Rated short circuit breaking current | kA | 12.5/16/20/25* | ||||
7 | Rated short current switching current(peak) | kA | 31.5/40/50/63* | ||||
8 | Rated peak value withstand current | kA | 31.5/40/50/63* | ||||
9 | 4S short time withstand current | kA | 12.5/16/20/25* | ||||
11 | Rated operating circulate |
| O-0.5S-CO-2S-CO-2S-CO | ||||
10 | Breaking current frequency under rated short circuit | time | 200 | ||||
12 | Mechanism life | time | 10000 | ||||
13 | Secondary loop 1 min power frequency withstand | kV | 2 | ||||
14 | Auxiliary voltage supply | Vac | 220±20% | ||||
15 | Battery bank | Vdc | 12×2 | ||||
16 | Capacitor unit | Vdc | 220 |
Rockwill's recloser gather multi relay protections like: | ||
EF1/EF2 | SEF1/SEF2 | Cold Load Pickup |
Live Load Blocking | Oscillography Capture capability | |
Programmable Logic | 4 Independent Protection Groups | |
Advanced Automation | Harmonic Protection and Monitoring | |
Hot Line Tag Capability | Negative Phase Sequence Overcurrent | |
Inverse Time Protection | Live Line Function & Hot Line Tag Function | |
Definite Time Protection | Directional Sensitive ground Fault Protection | |
Two fast-two slow curves | Phase (OV1) & Line-to-Line (OV2) Over Voltage | |
Temporary Time Addition | Directional over current and ground fault protection | |
Voltage Protection Element | Phase under-voltage balanced element (UV1) | |
Logic program-able function | Phase-to-Phase Under-voltage Element (UV2) | |
Zone Sequence Co-ordination | Loss of Supply (UV3) | |
High set Instantaneous element | Voltage Sag Protection (UV4 Sag) | |
Power Quality monitoring including Systems Performance Indices, Voltage Sags and Swells | ||
Voltage reclose control with automatic back feed(restoration provides loop automation functionality) |
If you want more functions, pls consult with us!
Part Number | RCW15M/630-20 | RCW27M/630-20 | RCW38M/630-20 |
Current Sensing | 3 x Current Transformers | 3 x Current Transformers | 3 x Current Transformers |
Voltage Sensing | 3 x Voltage Sensors | 3 x Voltage Sensors | 3 x Voltage Sensors |
Control Type | RWK-351 | RWK-351 | RWK-351 |
What is the standard of Rockwill Auto Recloser?
Rockwill Auto Recloser is a flexible pole mounted outdoor vacuum switching device that can trip and reclose up for a temporary distribution line fault. It reduces the blackout time greatly and improves the stability of power grid operation. The operation status also can be controlled and monitored by mobile phone and SCADA system.
Rockwill standard auto recloser is fully meet the Standard IEC62271-111 & ANSI/IEEE C37.60. Fully follow the above standard for type test and routine test. Additional functions reuirement is offered, like: ESKOM standard, TANESCO standard, BPC standard, SEC standard, DEC, Meralco, KPLC, BREB, etc. Besides, Rockwill even provide with patent design for new recloser.
RCW+ Auto Recloser
RCW+ type auto recloser is ANSI/IEC standardized plus design products which is equipped with one magnetic actuator mechanism, one manual closing/opening/Locking device, 3 current sensors, max 6 voltage sensors, with more functional like protection curves + curves programble, coodination logics + logics programble, programble communication protocols(Modbus, DNP3.0, IEC 60870-5-101/104), PC software, APP control tool, etc.
RCW+ type auto circuit recloser is a solid insulation reclosure with zero pressure Sf6 GAS sealed. with high creepage design, higher insulation level, suit using for Maximum 42kV level sytem.
It's vacuum interrupting technology, and IP67 IP protection class, It avoid any bad influence high polution enviroment of humidity, salt or alkali incursion or small animal,etc...
● Main technical data of auto recloser
N | Item | Unit | Data | ||||
1 | Rated max voltage | kV | 12 | 15 | 27 | 38 | |
2 | Rated current | A | 630/800/1250 | ||||
3 | Rated frequency | HZ | 50/60 | ||||
4 | Power frequency 1min | Dry | kV | 45 | 55 | 65 | 95 |
Wet | 30 | 45 | 55 | 80 | |||
5 | Lightning impulse withstand voltage(peak) | kV | 75/95* | 95/100* | 125/150* | 170/200* | |
6 | Rated short circuit breaking current | kA | 12.5/16/20/25* | ||||
7 | Rated short current switching current(peak) | kA | 31.5/40/50/63* | ||||
8 | Rated peak value withstand current | kA | 31.5/40/50/63* | ||||
9 | 4S short time withstand current | kA | 12.5/16/20/25* | ||||
11 | Rated operating circulate |
| O-0.5S-CO-2S-CO-2S-CO | ||||
10 | Breaking current frequency under rated short circuit | time | 200 | ||||
12 | Mechanism life | time | 10000 | ||||
13 | Secondary loop 1 min power frequency withstand | kV | 2 | ||||
14 | Auxiliary voltage supply | Vac | 220±20% | ||||
15 | Battery bank | Vdc | 12×2 | ||||
16 | Capacitor unit | Vdc | 220 |
Rockwill's recloser gather multi relay protections like: | ||
EF1/EF2 | SEF1/SEF2 | Cold Load Pickup |
Live Load Blocking | Oscillography Capture capability | |
Programmable Logic | 4 Independent Protection Groups | |
Advanced Automation | Harmonic Protection and Monitoring | |
Hot Line Tag Capability | Negative Phase Sequence Overcurrent | |
Inverse Time Protection | Live Line Function & Hot Line Tag Function | |
Definite Time Protection | Directional Sensitive ground Fault Protection | |
Two fast-two slow curves | Phase (OV1) & Line-to-Line (OV2) Over Voltage | |
Temporary Time Addition | Directional over current and ground fault protection | |
Voltage Protection Element | Phase under-voltage balanced element (UV1) | |
Logic program-able function | Phase-to-Phase Under-voltage Element (UV2) | |
Zone Sequence Co-ordination | Loss of Supply (UV3) | |
High set Instantaneous element | Voltage Sag Protection (UV4 Sag) | |
Power Quality monitoring including Systems Performance Indices, Voltage Sags and Swells | ||
Voltage reclose control with automatic back feed(restoration provides loop automation functionality) |
If you want more functions, pls consult with us!
Part Number | RCW15M/630-20 | RCW27M/630-20 | RCW38M/630-20 |
Current Sensing | 3 x Current Transformers | 3 x Current Transformers | 3 x Current Transformers |
Voltage Sensing | 3 x Voltage Sensors | 3 x Voltage Sensors | 3 x Voltage Sensors |
Control Type | RWK-351 | RWK-351 | RWK-351 |