126(145)kV HV Vacuum circuit breaker
  • 126(145)kV HV Vacuum circuit breaker
Key attributes
Brand ROCKWILL
Model NO. 126(145)kV HV Vacuum circuit breaker
Rated voltage 145kV
Rated frequency 50/60Hz
Series ZW
Product descriptions from the supplier
Description

Product introduction

The 126(145)kV HV Vacuum circuit breaker is a cutting - edge high - voltage electrical device designed to ensure the safe and efficient operation of power systems. Leveraging vacuum as the arc - extinguishing and insulating medium, it boasts exceptional performance in rapidly interrupting fault currents, preventing arc re - ignition, and maintaining stable insulation. Its robust construction and advanced operating mechanisms guarantee reliable switching capabilities, even under extreme conditions. Ideal for substations and critical transmission lines, this breaker combines high - voltage handling capacity with long - term durability, reducing maintenance needs and enhancing overall grid reliability.

Main characteristic

  • High - Voltage Rating: Designed for 126(145)kV, suitable for major transmission and distribution systems.

  • Vacuum - based Arc Extinction: Ensures rapid arc quenching and prevents re - ignition for reliable operation.

  • Robust Construction: Built to withstand extreme conditions, providing mechanical stability and durability.

  • Efficient Fault Interruption: Quickly cuts off fault currents to protect power grid equipment.

  • Low Maintenance: Long - lasting performance reduces the frequency of servicing requirements.

Main technical parameters

Instructions on placing orders 

  • Model and format of the circuit breaker.

  • Rated electrical parameters (voltage, current, breaking current, etc).

  • Working conditions for using (environment temperature, altitude, and environment pollution level).

  • Rated control circuit electrical parameters (Rated voltage of energy-store moter and Rated voltage of opening, closing coil).

  • Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered).

  • The wire connecting direction of the primary upper terminal.

 

Documentation Resource Library
Live Tank Breakers Catalog
Restricted.
Live Tank Breakers Catalog
Catalogue
English
Consulting
Consulting
FAQ
Q: What are the differences between this product and similar products from ABB/Siemens?
A:

The LW10B \ lLW36 \ LW58 series products in the sample booklet are porcelain column SF ₆ circuit breakers based on the ABB'LTB series improvement, with voltage coverage of 72.5kV-800kV, using Auto Buffer ™ Self powered arc extinguishing technology or vacuum arc extinguishing technology, integrated spring/motor driven operating mechanism, supports various customized services, covering 40.5-1100kV full voltage levels, with outstanding modular design and strong customization ability, suitable for projects that require flexible adaptation to different power grid architectures. Made in China, with fast global service response speed, high logistics efficiency, and high reliability at a reasonable price.

Q: What are the core differences between live tank circuit breakers and tank circuit breakers?
A:
  1. The core differences between porcelain column circuit breakers and tank circuit breakers—two main structural types of high-voltage circuit breakers—lie in six key aspects.
  2. Structurally, porcelain column types are supported by porcelain insulation pillars, with open-layout components like arc extinguishing chambers and operating mechanisms. Tank types use metal-sealed tanks to encapsulate and highly integrate all core parts.
  3. For insulation, the former relies on porcelain pillars, air, or composite insulating materials; the latter combines SF₆ gas (or other insulating gases) with metal tanks.
  4. Arc extinguishing chambers are mounted on the top or pillars of porcelain columns for the former, while built inside metal tanks for the latter.
  5. In application, porcelain column types suit outdoor high-voltage distribution with a dispersed layout; tank types adapt flexibly to indoor/outdoor scenarios, especially space-constrained environments.
  6. Maintenance-wise, the former’s exposed components enable targeted repairs; the latter’s sealed structure reduces overall maintenance frequency but requires full inspections for local faults.
  7. Technically, porcelain column types offer intuitive structure and strong anti-pollution flashover performance, while tank types boast excellent sealing, high SF₆ insulation strength, and superior resistance to external interference.
Q: What is a live tank circuit breaker? What voltage level is it suitable for they?
A:

live tank circuit breaker is a structural form of high-voltage circuit breaker, which is characterized by the use of ceramic insulation pillars to support key components such as arc extinguishing chamber and operating mechanism. The arc extinguishing chamber is usually arranged on the top or pillar of the ceramic pillar. It is mainly suitable for medium and high voltage power systems, with voltage levels covering the range of 72.5 kV to 1100 kV. live tank circuit breakers are common control and protection equipment in outdoor distribution devices such as 110 kV, 220 kV, 550 kV, and 800 kV substations.

Related Products
Related Solutions
Inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
IEE Business
Source professional electrical partners, experts, and explore smart grid & energy solutions.