占位边距

Products

China recloser,transformer,switchgear,EV charger,Digital power station Manufacturer

10kV Grade Three-phase Dry-type Grounding Transformer

  • 10kV Grade Three-phase Dry-type Grounding Transformer
Key attributes
Brand ROCKWILL
Model NO. 10kV Grade Three-phase Dry-type Grounding Transformer
Rated voltage 10kV
Rated frequency 50/60Hz
Rated capacity 1000kVA
Series DKSC
Product descriptions from the supplier
Description

Product Description

The 10kV Grade Three-phase Dry-type Grounding Transformer is a specialized electrical device designed to create an artificial neutral point in three-phase power systems that are otherwise ungrounded or impedance-grounded. Utilizing a robust resin-cast insulation system, it provides a safe, reliable, and maintenance-free solution for system grounding. Its primary function is to control transient overvoltages and provide a path for ground fault current, thereby enhancing the safety and stability of the entire 10kV distribution network.

Product model

  • DK: Grounding Transformer

  • S: Three-phase

  • C: Molded Solid

  • First □: Total Capacity (kVA)

  • Second □: Primary Voltage (kV)

  • Third □: Secondary Capacity (kVA)

  • Fourth □: Secondary Voltage (kV)

Product features

Grounding transformer neutral point and line connection, and for exactly neutral electrical grounding system of cattle light produced when the guest of the current can be reduced, the East set point, was sentenced to death for the export, improve the operation of the power system can be, the product conforms to the GB1094.6 "IEC60076-6", the standard for reactance

The product object, a small, high degree of organization. Day think, small volume, decent, calendar, and there can be 8 advantages, can be widely used in power transmission system, electric railway, metallurgy and other cities

Conditions of use

  • Ambient temperature is not higher than 40°C, and altitude does not exceed 1000m.

  • Protection levels are in forms such as IP00, IP20, and IP23.

  • Cooling methods include air natural cooling (AN) and forced air cooling (AF).

Technical Parameters of DKSC Grounding Transformer

Model Specification

Outline Dimensions (Length * Width * Height mm)

Foot Mounting Dimensions (mm)

Total Weight (Kg)

DKSC-250/10.5

1300 * 800 * 1300

660 * 700

900

DKSC-250/10.5

1300 * 800 * 1300

660 * 700

940

DKSC-400/10.5

1350 * 800 * 1300

660 * 700

1000

DKSC-400/10.5-100/0.4

1350 * 800 * 1300

660 * 700

1080

DKSC-630/10.5

1450 * 850 * 1500

660 * 800

1540

DKSC-630/10.5-100/0.4

1450 * 850 * 1500

660 * 800

1600

DKSC-700/10.5-100/0.4

1570 * 850 * 1500

660 * 800

1890

DKSC-800/10.5-200/0.4

1570 * 850 * 1600

660 * 800

1950

DKSC-1000/10.5

1500 * 1070 * 1600

820 * 1020

2000

DKSC-1000/10.5-315/0.4

1550 * 1070 * 1600

820 * 1020

2080

DKSC-1100/10.5-400/0.4

1550 * 1070 * 1600

820 * 1020

2150

DKSC-1200/10.5-200/0.4

1650 * 1070 * 1650

820 * 1020

2370

Note: the above parameters are for reference only and can be customized according to customer requirements.

 

Related Products
Related Solutions
Send inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO