Product Overview
The FN7-12DR Indoor AC High-Voltage Load Switch is a professional electrical switching device engineered for 3-phase AC 50Hz power systems with a rated voltage of 12kV. It is primarily designed for reliable making and breaking of load currents, as well as closing short-circuit currents in medium-voltage distribution networks. When integrated as a combined electrical apparatus, it can interrupt all current types up to short-circuit current, serving as an efficient protective component for indoor power distribution systems and ensuring safe, stable operation of electrical grids.
Compliant with international IEC and national high-voltage electrical equipment standards, the FN7-12DR features a compact structural design, easy operation and installation, and strong adaptability to various indoor working environments. It is a core switching and protection device for indoor medium-voltage power distribution in industrial and commercial facilities, substations and distribution rooms.
Core Features
- Multi-Current Operation Capacity: Specialized for breaking load currents and closing short-circuit currents; combined apparatus version can interrupt all current levels up to short-circuit current, realizing integrated switching and protection.
- Standardized Design & Compliance: Adheres to international and national high-voltage electrical equipment standards, with reliable performance and global market applicability.
- Compact Indoor Structure: Optimized compact design, suitable for limited installation space in indoor distribution rooms, substations and electrical cabinets, saving layout space.
- Stable & Durable Performance: Adopts high-quality electrical components and mechanical structures, with strong resistance to wear and electrical aging, ensuring long-term stable operation under rated working conditions.
- Easy Operation & Maintenance: Humanized operating mechanism, supporting manual operation with simple operation steps; low daily maintenance requirements, reducing post-use operation costs.
- Integrated Protection Function: The combined electrical apparatus type can act as a dedicated protective device, effectively isolating fault currents and protecting the safety of subsequent electrical equipment and power grids.
Technical Parameters
|
Rated Voltage (KV, RMS)
|
12
|
FN7 - 12/630A
|
|
Insulation Level - Power - frequency Withstand Voltage for 1 minute (KV, RMS)
|
Inter - phase, Phase - ground: 42
|
Isolating Gap: 48 |
|
Insulation Level - Lightning Impulse Withstand Voltage (KV, Peak Value)
|
Inter - phase, Phase - ground: 75
|
Isolating Gap: 85 |
|
Rated Current (A)
|
400
|
630
|
|
Rated Thermal - stability Current (KA, RMS for 4S)
|
12.5
|
20
|
|
Rated Dynamic - stability Current (KA, Peak Value)
|
31.5
|
50
|
|
Rated Short - circuit Making Current (KA, Peak Value)
|
31.5
|
50
|
|
Rated Voltage (KV, RMS)
|
12
|
FN7 - 12/630A
|
DX (Grounding Switch at Outgoing Line End)
|
L (Interlocking Device)
|
R (Fuse)
|
RA (Punch - Type Fuse)
|
F (Electric Opening Device)
|
Application
|
|
Insulation Level - Power - frequency Withstand Voltage for 1 minute (KV, RMS)
|
Inter - phase, Phase - ground: 42
|
Isolating Gap: 48 |
—
|
-
|
—
|
—
|
—
|
Line Load Switch, Transformer Protection
|
|
Insulation Level - Lightning Impulse Withstand Voltage (KV, Peak Value)
|
Inter - phase, Phase - ground: 75
|
Isolating Gap: 85 |
—
|
△
|
—
|
—
|
—
|
|
|
Rated Current (A)
|
400
|
630
|
△
|
△
|
|
|
|
|
|
Rated Thermal - stability Current (KA, RMS for 4S)
|
12.5
|
20
|
—
|
—
|
△
|
—
|
—
|
|
|
Rated Dynamic - stability Current (KA, Peak Value)
|
31.5
|
50
|
—
|
△
|
△
|
—
|
—
|
|
|
Rated Short - circuit Making Current (KA, Peak Value)
|
31.5
|
50
|
△
|
△
|
△
|
—
|
—
|
|
|
Load Switch - Punch Type
|
FN7 - 12RAF
|
-
|
—
|
—
|
—
|
△
|
△
|
|
|
Load Switch - Punch Type
|
FN7 - 12DSLRAF
|
△
|
—
|
△
|
—
|
△
|
△
|
|
|
Load Switch - Punch Type
|
FN7 - 12DXLRAF
|
-
|
△
|
△
|
—
|
△
|
△
|
|
Note: (-) means not available; (△) means available.
Application Scenarios
- Indoor Distribution Rooms & Substations: Core switching device for 12kV medium-voltage power distribution, used for load regulation and fault protection in indoor power supply systems.
- Industrial and Mining Enterprises: Applied in indoor electrical control systems of factories, mines and processing plants, adapting to the high-demand power distribution and protection needs of industrial production.
- Commercial and High-Rise Buildings: Used for indoor medium-voltage power distribution of shopping malls, office buildings and high-rise residential buildings, ensuring safe and continuous power supply for building electrical systems.
- Power Grid Auxiliary Distribution: Serving as the switching and protection device for the indoor auxiliary power supply network of 12kV grade substations and power distribution stations.
- Switchgear Integration: Integrated into indoor high-voltage switchgear as a core functional unit, forming a complete power distribution and protection system for various industrial and civil scenarios.
Quality Advantages
- High-Quality Component Selection: Adopts high-grade conductive, insulating and mechanical components, ensuring the product's electrical performance and mechanical strength meet long-term operation requirements.
- Strict Factory Testing: Each FN7-12DR load switch undergoes rigorous electrical performance and mechanical performance testing before leaving the factory, eliminating defective products and ensuring consistent product quality.
- Strong Environmental Adaptability: Designed for indoor working environments, with good resistance to dust, humidity and slight temperature changes, adapting to various indoor power distribution site conditions.
- Mature Manufacturing Process: Adopts advanced production and processing technology, with precise structural assembly, reducing mechanical failure rates and improving the overall reliability of the product.
Installation & Maintenance Notes
- Installation: Should be installed in a dry, dust-free indoor environment, with strict compliance with the installation manual for wiring and fixing to ensure sufficient insulation distance between components.
- Operation: Operators must have professional electrical operation qualifications; strictly follow the operating procedures to avoid misoperation caused by illegal operation.
- Daily Maintenance: Regularly inspect the appearance of the product for damage, loose fasteners and poor contact of conductive parts; clean the insulating parts regularly to remove dust and dirt.
- Fault Handling: In case of abnormal operation, cut off the power supply in time for inspection and maintenance; do not disassemble the product without professional guidance to avoid secondary damage.