Indoor Metal-Clad with Drawable Switchgear for Primary Distribution

  • Indoor Metal-Clad with Drawable Switchgear for Primary Distribution
Key attributes
Brand ROCKWILL
Model NO. Indoor Metal-Clad with Drawable Switchgear for Primary Distribution
Rated voltage 12kV
Rated frequency 50/60Hz
Series Kyn28
Product descriptions from the supplier
Description

Product Description

KYN28A-12 Steel-clad Removable-type Metal-enclosed Switchgear (hereinafter called switchgear for short) is applicable in the power system of three phases 50/60HZ. which is used to receive and distribute power as well as control. protect and moniter the circuit of power plant, substation and industrial and mining enterprises and high-rise buildings.

KYN28A-12 switchgear has the function of preventing various wrong operations including preventing loading mobile handcart, preventing grounding switch to circuit the breaker in closed position, preventing to close the charged grounding switch and preventing straying into charged compartment and other functions. Switchgear is equipped with excellent mid-set type of VS1, VD4 series high voltage vacuum circuit breaker and enclosed type vacuum circuit breaker. The secondary loop configuration of the switchgear is advanced and reliable control protection devices: Busbar with heat insulation materials or the insulation of the epoxy coating methods, optimizes the electrode shape and compacts the structure. The switchgear is safe and reliable power distribution equipment with advanced technology. stable performance, reasonable structure and easy usage. 

Service condition

  • Air temperature: Maximum temperature: +40ºC; Minimum temperature:-15ºC
  • Humidity: Monthly average humidity 95%; Daily average humidity 90% .
  • Altitude above sea level: Maximum installation altitude: 1000M.
  • Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
  • No frequent violent shake

Main characteristics

Adopt an intelligent switch cabinet operating system

  • The circuit breaker of the switch cabinet enters, exits, opens and closes to realize remote control or local electric operation.
  • The grounding switch of the switch cabinet is opened and closed to realize remote control or local electric operation.
  • All primary contact parts in the switch cabinet adopt visual interface and temperature measurement methodsto ensure the safe connection of all contacts.

2.Adopt intelligent information processing system to diagnose and monitor the failure precursor of the switchgear body

  • On-line detection and over-limit monitoring of busbar and cabinet temperature.
  • On-line monitoring of operating characteristics of circuit breaker opening and closing speed.
  • Online monitoring of the mechanical performance of the operating mechanism.
  • Online detection and alarm of insulation level.

3. Intelligent anti-misoperation operating system

  • Prompts and previews of various operations.
  • Check the operation and lockout of misoperation.
  • Prohibit operation prompts and operating condition prompts.

4. Intelligent function of secondary circuit

Intelligent measurement, signal, protection, control and movement.

5. Remembrance of grid failure

Wave recording, login, simulation replay and fault recording, provide analysis data.

Technical Sheet

Technical specification Unit Data
Rated voltage kV 3.6,7.2,12
Rated frequency Hz 50/60
Circuit breaker rated current A 630, 1250, 1600, 2000, 2500, 3150, 4000
Rated current of switchgear A 630, 1250, 1600, 2000, 2500, 3150, 4000
Rated short-time withstand current (4s) kA 16,20,25,31.5,40,50
Rated peak withstand current (peak value) kA 40,50,63,80,100,125
Rated short-circuit breaking current kA 16,20,25,31.5,40,50
Rated short-circuit making a current (peak value) kA 40,50,63,80,100,125
Rated insulation level 1min power frequency withstand voltage interpolar, Between poles kV 24,32,42
between open contacts kV 24,32,48
Lightning impulse withstand voltage (peak value) interpolar, Between poles kV 40,60,75
between open contacts kV 46,70,85

Main primary part

SF6 load break switch

SF6 load break switch used in the modular switchgear has multiple functions for 3 working positions, combined with grounding switch and isolation switch. With 0.045 Map SF6 gas filled in a fully sealed epoxy resin enclosure that make its structure enhanced and good insulation performance.
Thanks to its design, it ensures the quality and reliability for its's proper operation in switchgear control.
Its's mechanical and electrical interlocking systems between the load break switch and the earthing switch, possibility of a wrong-man oeuvre is prevented by these interlocking systems.

Indoor Metal-Clad with Drawable Switchgear for Primary Distribution

Vacuum circuit breaker
The VS1 (VN) vacuum circuit breakers are designed with solid sealed pole type, side-mounted installed, and high mechanical stability. It can be used to store energy with AC and DC power supply, and also be used by manually. It has the advantages of compact size, strong breaking capacity, high insulation strength, no pollution, no danger of explosion and etc.

  • Spring/ permanent magnetic operating mechanism for option.
  • Vacuum interrupter and operating mechanism are installed in a front and rear way, and connected through whole transmission mechanism
  • Reliable performance and free maintenance under frequently operation

Indoor Metal-Clad with Drawable Switchgear for Primary Distribution

 
Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO