Product Overview
This Manual Cable-Outgoing Pole-Mounted SF6 Load break Switch is a high-performance outdoor switching device engineered for medium-voltage power distribution systems, optimized for pole-mounted installation and manual cable-outgoing application scenarios. Adopting high-purity SF6 gas as insulation and arc-extinguishing medium, it features ultra-fast arc extinction, stable mechanical performance, and comprehensive safety protection, fully complying with international IEC high-voltage equipment standards.
Ideal for urban and rural overhead distribution networks, industrial outdoor power supply, and rural grid upgrading projects worldwide, the switch excels in frequent load switching, accurate power parameter collection, and reliable fault protection. Its flexible structural design and multi-scenario adaptability perfectly meet the procurement requirements of overseas clients for high-reliability, low-maintenance pole-mounted SF6 switching equipment.
Technical Advantages
- High-Purity SF6 & Ultra-Fast Arc Extinction:Filled with SF6 gas of purity above 99.9%, the switch achieves an arc extinction time of ≤10ms (1/2 cycle) with excellent insulation recovery performance. Minimal contact wear at the breaking part eliminates the need for inspection, maintenance or replacement, greatly reducing lifecycle costs and on-site operation difficulty.
- Dual Spring Energy-Storage Operating Mechanisms:Equipped with two types of spring energy-storage mechanisms: the pre-energy storage mechanism completes opening/closing in ≤0.06s, and the direct energy storage mechanism in ≤0.6s. Both mechanisms feature stable action and perfect compatibility with backup protection devices, ensuring fast and coordinated fault handling in power distribution systems.
- Zero Pressure Reliable Operation:The switch maintains its rated insulation level and breaking capacity even at zero gauge pressure (0 kg・f/㎠ = 0.0 MPa), avoiding operational failure caused by accidental gas pressure loss and providing an extra layer of safety for outdoor long-term operation.
- Flexible Structural & Outgoing Line Design:The inlet and outlet bushings support porcelain and organic material options, with cable-type or terminal-type outgoing line modes available for free selection. This flexible design adapts to different installation and wiring requirements of overseas power distribution projects, improving on-site adaptability.
- High-Pressure Explosion-Proof Pressure Relief Protection:Integrated with a high-pressure explosion-proof pressure relief device to prevent cabinet rupture caused by abrupt internal gas pressure rise due to abnormalities. The explosion-proof safety diaphragm withstands a pressure of 4-6 kg・f/㎠ (0.4-0.6 MPa), effectively protecting on-site personnel and surrounding equipment.
- Dual Locking & Low-Pressure Alarm:Equipped with a low air pressure locking alarm device and a manual locking device. The low-pressure alarm promptly reminds of gas leakage, and the mechanical locking function prevents unsafe operation, while manual locking meets the safety requirements of on-site maintenance.
- Built-In Precision Transducers for Parameter Collection:Integrated with 3 current transformers (CT), 1 set of zero-sequence current transformers (ZCT), and 6 voltage transformers (VT) to accurately collect real-time operation parameters of the distribution network, laying a foundation for intelligent monitoring and fault analysis:
CT: 600/1000:1 ratio (SP ratio optional);
ZCT: 600/1000:1 ratio, IA, 0.5 accuracy class (ratio optional);
VT: 3 on power supply side (A/B/C) & 3 on load side (S/T), phase voltage ratio 0.4-37V (optional), stable 1.0% accuracy.
- Comprehensive Transducer Protection Systems:Configured with dedicated CT/ZCT protection devices to prevent overcurrent and open circuit of current and zero-sequence current sensors, and independent voltage sensor protection devices to avoid overvoltage damage to phase and zero-sequence voltage sensors, effectively extending the service life of internal components.
- Flexible & Safe Operation Modes:Supporting basic manual operation, the switch is optional with remote control opening/closing function (customizable), realizing flexible switching between local and remote operation. All operation modes are designed for simplicity, speed and safety, adapting to different on-site operation management needs of overseas projects.
Technical Parameters
|
Model Number
|
|
LBS-12
|
LBS-24
|
LBS-40.5
|
|
Rated Voltage
|
kV
|
12
|
24
|
40.5
|
|
Rated Current
|
A
|
630
|
630
|
630
|
|
Rated Frequency
|
Hz
|
50/60
|
50/60
|
50/60
|
|
Insulation Level
|
Break Gap
|
Power Frequency (Dry and Wet Test)
|
kV
|
48
|
79
|
110
|
|
Lightning Impulse Test Voltage (Peak Value)
|
kV
|
85
|
145
|
215
|
|
To Ground and Between Phases
|
Power Frequency
|
Dry Test
|
kV
|
42
|
64
|
95
|
|
Wet Test
|
kV
|
34
|
50
|
70
|
|
Lightning Impulse Test Voltage (Peak Value)
|
kV
|
75
|
125
|
185
|
|
Breaking Capacity
|
Rated breaking current
|
A
|
630
|
630
|
630
|
|
Rated maximum breaking current (blocking current)
|
A
|
900
|
900
|
900
|
|
Rated thermal stability current (effective value)
|
kA
|
20
|
20
|
20
|
|
Rated thermal stability time
|
s
|
4
|
4
|
4
|
|
Rated short - circuit making current/Rated dynamic stability current (peak value)
|
kA
|
50
|
50
|
50
|
|
Mechanical Characteristics
|
Direct energy - storage mechanism (M)
|
Closing time
|
ms
|
700-1000
|
|
Opening time
|
ms
|
700-1000 |
|
Pre - energy - storage mechanism (K)
|
Closing time
|
ms
|
35-70
|
|
Opening time
|
ms
|
35-70
|
|
Closing speed
|
m/s
|
1.8±0.4
|
|
Opening speed
|
m/s
|
1.8±0.4
|
|
Three - phase non - simultaneity
|
ms
|
≤3
|
|
Mechanical life
|
Times
|
>10000
|
>10000
|
>10000
|
|
Others
|
Rated inflation pressure (20°C)
|
MPa
|
0.05
|
0.07
|
0.1
|
| |
SF₆ gas annual leakage rate
|
%/year |
<0.1/year
|
- Urban & Rural Overhead Distribution Grids: Pole-mounted installation for 10kV/12kV feeder lines, suitable for load switching and fault isolation in urban communities, rural villages and suburban areas.
- Industrial Outdoor Power Supply: Applied in factories, mines and industrial parks for outdoor pole-mounted power distribution, withstanding harsh on-site environments and frequent operation requirements.
- Rural Grid Upgrading & Renovation: An ideal upgrading device for rural power distribution networks, improving power supply reliability and intelligent monitoring level.
- Suburban & Remote Area Power Distribution: Adapted to pole-mounted power distribution in remote areas with complex terrain, featuring easy installation and low maintenance.
- Commercial & Public Facility Outdoor Power Supply: Used for outdoor power distribution of shopping malls, schools, hospitals and other public facilities, ensuring stable and safe power supply for critical loads.