占位边距

MV Outdoor Vacuum Circuit-breaker for substation

  • MV Outdoor Vacuum Circuit-breaker for substation
Key attributes
Brand ROCKWILL
Model NO. MV Outdoor Vacuum Circuit-breaker for substation
Rated voltage 12kV
Rated normal current 2500A
Rated short circuit breaking current 31.5kA
Series OVCB
Product descriptions from the supplier
Description

Product overview

By combining the latest developments in circuit breaker technology with world-renowned quality,Type OVCB Vacuum Substation Circuit Breakers are the advanced medium-voltage circuit breakers available.

  • Compliance to IEC/IEEE/ANSI standards

Designed and tested to comply with IEC/IEEE/ANSI standards.

  • ISO 9001 certification

Designed and manufactured in a facility certified by ISO 9001.

  • High seismic construction

High seismic construction according to ETGI-1.020/IEEE-693.

Mian feature

  • High-speed operation - Interrupting time of three cycles or less.
  • Long life - Embedded pole interrupter protect contacts from corroding elements and contamination.
  • Ease of maintenance - Interrupter assemblies and contact wear indicators accessible via a bolted panel.
  • Reliability - A minimum of moving parts on the proven motor-driven, spring-charged modular operating mechanism.
  • Durability - vacuum circuit breakers adopt special convection ventilation technology, with ultra-low resistance vacuum interrupter, greatly reducing temperature rise caused by long-term operation of vacuum circuit breaker and reducing power loss.

Standard configuration

  • Porcelain dry-type bushings with extended creepage.
  • Multi-ratio bushing-type CTs for measurement & protection.
  • Window for viewing status indicators and operation counter.
  • Standard configuration for 1-closing coil and 2-opening coils.
  • 12-pole auxiliary switch (6 'a' & 6 'b' contacts), latch check switch.
  • Modular operating mechanism with integral manual charging handle.
  • Available for extended CT, PT, Meter, Relay mounting in IP55 metal enclosure.

Product structure

Technical Parameters

Project

Unit

Data

Rated voltage

kV

7.2/12

16.5/24

33/36/40.5

Rated current

A

630,1250,

1600,2000,

2500,3150

630/1250,

1600,2000,

2500/3150

1250,1600,

2000,2500

Rated frequency

Hz

50/60

50/60

50/60

Rated insulation level

       

Rated lightning impulse withstand voltage(1min(effective value))

kV

42

65

95

Rated power frequency withstand voltage - BIL(peak value)

kV

75

125

185

Rated short circuit breaking current

kA

20/25/31.5/40

20/25/31.5/40

25/31.5/40

Rated short time withstand current(4s)

kA

20/25/31.5/40

20/25/31.5/40

25/31.5/40

Rated peak withstand current(peak values)

kA

50/63/80/100

50/63/80/100

63/80/100

Operating mechanism type

 

Motor drive spring mechanism

Rated operating sequence

 

Ics ≤ 40kA: O-0.3s-CO-180s-CO

Isc = 40kA: O-180s-CO

Rated short-circuit current breaking times/electrical endurance

level

E2(EC2271-100)

Mechanical endurance

No of times

10000

Rated auxiliary control voltage

V

AC220/110, DC220/110

Opening time

ms

20~50

20~50

20~60

Arcing time

ms

10~15

10~15

≤15

Full opening time

ms

30~65

30~65

30~65

Closing time

ms

35~70

35~70

35~70

Enclosure protection level

 

IP55

 

Application scenarios

  • 12kV-40.5kV outdoor medium voltage distribution system;
  • Circuit control and protection of outdoor substations and distribution stations;
  • Severe outdoor environments such as frequent earthquakes, high altitudes, and high pollution;
  • Industrial and municipal distribution network projects that require high reliability.

Dimension

MV Outdoor Vacuum Circuit-breaker for substation

FAQ
Q: What are the types of operating mechanisms and control voltages available, and is manual emergency operation supported?
A:


The operating mechanism is a motor-driven spring mechanism, supporting dual-mode operation of electric and manual. The standard auxiliary control voltage is AC220/110V and DC220/110V, which is compatible with most distribution system control circuits. Manual operation is achieved through an integrated energy storage handle, which is suitable for emergency scenarios such as power outages, and can be opened and closed without the need for additional tools.

Q: What is the difference between vacuum circuit breaker and SF6 circuit breaker?
A:
  1. Their core difference is arc-extinguishing media: Vacuum breakers use high vacuum (10⁻⁴~10⁻⁶Pa) for insulation and arc extinction; SF₆ breakers rely on SF₆ gas, which adsorbs electrons well to quench arcs.
  2. In voltage adaptation: Vacuum breakers fit medium-low voltages (10kV, 35kV; some up to 110kV), rarely 220kV+. SF₆ breakers suit high-ultra high voltages (110kV~1000kV), mainstream for ultra-high voltage grids.
  3. For performance: Vacuum breakers extinguish arcs fast (<10ms), have 63kA~125kA breaking capacity, suit frequent use (e.g., power distribution) with long life (>10,000 cycles). SF₆ breakers excel in stable large/inductive current breaking but work less frequently, needing insulation recovery time post-extinction.
  4. Compared to SF6 gas circuit breakers, vacuum circuit breakers can achieve zero greenhouse gas emissions and are more environmentally friendly because the arc extinguishing device does not contain any gas

Related Products

Related Solutions

Send inquiry
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO