Outdoor High-Voltage AC SF6 Bypass Load break Switch 12kV 24kV

  • Outdoor High-Voltage AC SF6 Bypass Load break Switch 12kV 24kV
Key attributes
Brand ROCKWILL
Model NO. Outdoor High-Voltage AC SF6 Bypass Load break Switch 12kV 24kV
Rated voltage 12kV
Rated normal current 200A
Rated frequency 50/60Hz
Series LBS
Product descriptions from the supplier
Description

Product Overview
The Outdoor High-Voltage AC SF6 Bypass Load break Switch is a high-reliability, durable switching device engineered for outdoor medium and high-voltage AC power distribution systems. Integrating advanced SF6 gas insulation and arc-extinguishing technology with a specialized bypass design, it is designed to realize safe load transfer and equipment maintenance without power interruption, while boasting low power loss, excellent heat dissipation, and strong overload capacity.Compliant with international IEC standards, this switch features corrosion-resistant 304 stainless steel housing, stable mechanical performance, and flexible operation modes, making it an ideal core component for global urban and rural power grids, industrial facilities, and commercial infrastructure projects. It perfectly meets the procurement needs of overseas clients for high-quality, low-maintenance, and safe bypass switching equipment.

Core Features 

Focusing on durability, stability, and operability, the switch has distinct competitive advantages that align with the core demands of overseas purchasers:

  • Permanent Corrosion Resistance: The switch cabinet is manufactured with 304 stainless steel, which achieves permanent corrosion resistance, effectively adapting to harsh outdoor environments such as coastal areas, chemical plants, and high-humidity regions, and ensuring long-term stable operation without cabinet damage.
  • Stable & Durable Mechanical Performance: The main circuit operating mechanism adopts a simple toggle (inverted triangle) structure, which is not affected by high-frequency vibration, gravity, or external impact caused by earthquakes or strong winds. It features excellent operational stability, long mechanical service life, and supports both manual and electric closing/opening operations. It also has good compatibility with backup protection devices, ensuring seamless coordination in power system protection.
  • Flexible Quick-Plug Bushings: Equipped with quick-plug bushings, and optional European and American self-locking quick-connect plug-in interfaces, which greatly simplifies on-site installation, disassembly, and maintenance, improving construction efficiency and reducing labor costs.
  • Comprehensive CT/RVT Protection: Configured with CT/RVT protection device to prevent overcurrent and CT open circuit of current measurement devices, as well as overvoltage of voltage measurement devices, effectively protecting the switch and associated power equipment from damage, and ensuring the safe and stable operation of the power distribution system.
  • Rich Monitoring & Detection Functions: Equipped with live display, counting display, and phase checking function, which facilitates on-site operation, equipment status monitoring, and fault judgment, reducing the difficulty of on-site maintenance.
  • Multi-Mode Safe Operation: Supports manual operation, electric operation, on-site remote control operation; optional long-distance remote control closing/opening function, ensuring convenient, fast, and safe operation, and adapting to different on-site operation needs of overseas projects.
  • Optional Fault Protection (Customizable): Optional fault detection, alarm, and automatic fault cutoff functions, which can timely identify equipment faults, issue alarms, and automatically cut off faulty circuits, facilitating quick fault handling and reducing downtime, thus improving the reliability of the power distribution system.

Key Technical Specifications

1
Structure Form
Common Box Type
Common Box Type
2
Arc - extinction Medium / Insulation Medium
SF6 arc - extinction / SF6
SF6 arc - extinction / SF6
3
Rated Voltage (kV)
12
24
4
Rated Current (A)
200/400/630
200/400/630
5
Temperature - rise Test Current
1.1Ir
1.1Ir
6
 
Rated Power - frequency Withstand Voltage for 1min (kV)
 
 Relative Ground/Phase - to - phase
45
65
Breaker Gap
55
79
7
Rated Short - time Withstand Current and Duration (kA/s)
20/4
20/4
8
Rated Peak Withstand Current (kA)
50
50
9
Rated Short - circuit Making Current (kA)
20
20
10
Rated Short - circuit Breaking Current (kA)
50
50
11
Main Circuit Resistance (μΩ)
≤130
≤130
12
Mechanical Stability (times)
≥5000
≥5000
13
Phase Spacing (mm)
132 ± 2mm
132 ± 2mm
14
Rated Current Making and Breaking Times (times)
≥400 times
≥400 times
15
Operating Mode
Electric, with Manual Operation Function
16
Operating Voltage (V)
DC24
 
17
Different Periods of Opening and Closing (ms)
≤3
18
Closing Speed (m/s)
1.8 ± 0.4 (m/s)
19
Opening Speed (m/s)
1.8 ± 0.4 (m/s)
20
Opening and Closing Time (ms)
≤1000
21
Breaker Gap Distance (mm)
≥40
22
SF6 Gas Annual Leakage Rate
≤0.1%
23
Protection Class of Switch Housing
IP67
24
Service Life of Switch
30 years
25
Transportation Weight (kg)
95
Current Sensor​
Rated Current Ratio
Phase Current: 600A/1A; 1000A/1A
Accuracy Class
Phase Current: Protection 5P10 class, Measurement 0.5 class
Voltage Sensor​
Transformation Ratio
A/B/C; R/S/T; 6 - phase voltage sensors: Phase Voltage V / 0.4 - 37V (transformation ratio selectable)
Accuracy Class
0.5 class

Application Scenarios

With its specialized bypass function, durable corrosion-resistant design, and flexible operation, the switch is widely used in global outdoor high-voltage AC power distribution systems, especially suitable for:

  • Urban & Rural Power Grids: Bypass switching for 12kV/24kV outdoor overhead feeder lines, facilitating line maintenance and fault handling without interrupting user power supply, improving power supply reliability.
  • Industrial Facilities: Factories, mines, industrial parks, and chemical plants, where the 304 stainless steel cabinet resists corrosion, and the bypass function ensures uninterrupted production during equipment maintenance.
  • Commercial & Public Infrastructure: Shopping malls, hospitals, data centers, and high-rise buildings, providing reliable bypass switching for outdoor power distribution lines, ensuring uninterrupted power supply to critical loads.
  • Coastal & Harsh Environments: Coastal areas, high-humidity regions, and areas with severe air pollution, where the permanent corrosion-resistant design extends the service life of the switch.
  •  Renewable Energy Projects: Solar and wind farm outdoor distribution systems, used as bypass switching devices to ensure stable operation during equipment maintenance and load transfer.
  • International EPC Projects: Compliant with IEC standards, suitable for overseas engineering, procurement, and construction projects, adapting to different regional technical and environmental requirements.
Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO