Key attributes
Brand ROCKWILL
Model NO. Outdoor HV vacuum circuit breaker manufacturer 24kV 36kV 40.5kV
Rated voltage 40.5kV
Rated normal current 1250A
Rated frequency 50/60Hz
Series RVB
Product descriptions from the supplier
Description

Product Overview

Our 36kV Outdoor High-Voltage Vacuum Circuit Breaker is a robust AC three-phase switching device engineered for 50Hz power systems with a rated voltage of 36kV. Primarily deployed in rural and urban substations and 36kV distribution grids, it safely opens and closes load current, overload current, and short-circuit current to protect critical power infrastructure. Featuring porcelain insulation for superior anti-condensation, aging resistance, and temperature tolerance, this outdoor breaker delivers reliable performance in harsh environments. Compliant with IEC 62271-100, it is optimized for pole-mounted or substation applications, making it an ideal choice for global power grid operators, contractors, and bulk procurement projects.
Core Features
This 36kV outdoor vacuum circuit breaker is designed for durable, maintenance-friendly operation in outdoor power distribution systems. Its core features include:
  • Porcelain Insulation: Utilizes high-grade porcelain as the primary insulation material, offering excellent resistance to condensation, aging, and extreme temperatures for long-term reliability.
  • Compact & Reliable Design: Integrates a vacuum arc-extinguishing chamber, insulating rod, connecting rod, and three-pole epoxy pillar within a single mechanism casing, ensuring a small footprint and high operational stability.
  • Flexible Installation: Suitable for both pole-mounted and substation applications, with a robust structure that adapts to diverse outdoor deployment scenarios.
  • Weatherproof Protection: Equipped with a waterproof control box and built-in heater to prevent moisture buildup in the control room, eliminating performance issues in high-humidity environments.
  • Long Service Life: Vacuum arc-extinguishing technology minimizes wear and tear, reducing maintenance frequency and extending the product’s operational lifespan.
  • IEC Standard Compliance: Fully meets the requirements of IEC 62271-100, ensuring global compatibility and adherence to international safety and performance standards.

Technical data

Circuit-breaker on Column   RVB-24 RVB-36 RVB-40.5
Standard IEC 62271-100
Rated voltage (kV) 24 36 40.5
Rated insulation voltage (kV) 24 36 40.5
Power frequency withstand (kV /min) 70 (dry) / 70 (wet) 95 (dry) / 95 (wet) 95 (dry) / 95 (wet)
Impulse withstand voltage (kV peak) 170 170 195
Rated frequency (Hz) 50-60 50-60 50-60
Rated normal current (Amps) 1250 2000 2500 1250 2000 2500 2000 2500
Rated symmetrical breaking capacity (kA r.m.s) 25 25 31.5 25 25 31.5 31.5 31.5
Rated short time withstand current (3s) (kA r.m.s) 25 25 31.5 25 25 31.5 31.5 31.5
Asymmetrical breaking capacity (% of d.c Component at t=45ms) 35 35 35
Rated making capacity (kA peak) 63 63 80 63 63 80 80 80
Operating sequence 0-0.3sec- CO - 3 Min -CO & CO-15sec- CO
Opening time (ms) 45 ± 10 45 ± 10 45 ± 10
Capacitor current switching capacity (Amps)      
Single bank - C2 class 400 400  
Back to back - C2 class     750
Arcing time (ms) 5-15 5-15 5-15
Total breaking time (ms) 50-60 50-60 50-60
Closing time (ms) 75 ± 10 75 ± 10 75 ± 10
Over all dimensions On Frame (H x L x P) mm (3090-3840) x 900 x 686
Weight (kg) 850/900 850/900 900
N2 gas absolute pressure (kPa) for Anticondensation 150 150 150
Operating temperature #1 -25…+40 -25…+40 -25…+40
Tropicalization IEC:60068-2-30,721-2-1
Electromagnetic compatibility IEC 62271-1,61000-6-2,61000-6-4
Solar radiation (W/m2) 1000 1000 1000
Presence of pollution IEC 60815-Table 1 Level III Level III Level III
Creepage distance (mm/kV) 25 #2 25 #2 27.5 #2
Ice coating (mm) 10
Wind speed (m/s) 34
Earth quake resistance (g) 0.6
Surface force on the terminal Logitudinal xTransversal x Vertical ( N) 750 x 500 x 750

Service Environment

Engineered to withstand extreme outdoor conditions, this 36kV vacuum circuit breaker operates reliably under the following parameters:
  • Ambient Temperature: -40℃ to +85℃, with a daily average of 25℃
  • Altitude: ≤3000m (higher altitudes available via technical customization)
  • Wind Speed: Up to 35m/s
  • Icing Thickness: Up to 10mm
  • Seismic Intensity: ≤8 degrees
  • Ambient Air Contamination: ≤ Class III
  • Relative Humidity: Daily average ≤95%, monthly average ≤90%
  • Saturated Vapor Pressure: Daily average ≤2.2×10⁻³MPa, monthly average ≤1.8×10⁻³MPa

Key Application Scenarios

The 36kV Outdoor High-Voltage Vacuum Circuit Breaker is widely used in global power distribution projects, including:
  • Rural and urban 36kV substation power grids
  • Pole-mounted distribution line protection
  • Industrial and commercial power distribution systems
  • Remote power infrastructure in harsh climates
  • Power grid modernization and upgrade projects

Related Products

Related Solutions

Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO