Reliable interlocking solid insulated ring main unit (RMU)

  • Reliable interlocking solid insulated ring main unit (RMU)
Attributs clés
Marque ROCKWILL
Numéro de modèle Reliable interlocking solid insulated ring main unit (RMU)
tension nominale 12kV
fréquence nominale 50/60Hz
Série RMR
Descriptions de produits du fournisseur
Description

Product Details

YVG-12 series solid insulation ring network switchgear is a fully insulated, fully sealed, and maintenance free solid   insulation vacuum switchgear.

The  ring  network  cabinet  has  the  characteristics  of  simple  structure,  flexible  operation, reliable  interlocking,  and convenient installation, and is suitable for 50Hz, 12 kV power systems. It is widely used in industrial and civil cable ring networks and distribution network terminal projects, as a means of receiving and distributing electricity, especially suitable for urban residential distribution, industrial and mining enterprises Used in airports, subways, wind power generation, tunnels, and other places.

Suitable for use in areas with harsh environments such as high altitude, high temperature, humid heat, severe pollution, etc.

Standards: IEC62271-1-200  IEC62071-2000-2003

Selection

Reliable interlocking solid insulated ring main unit (RMU)

Classified by functional units in the system: incoming cabinet, outgoing cabinet, buscouple cabinet, metering cabinet, PT  cabinet, lifting cabinet, etc., represented by wiring scheme number. According to the type of main switch components, it is divided into: load switch cabinet, load switch fuse combination electrical cabinet, circuit breaker cabinet, and isolation switch cabinet, etc., represented by F (fuse combination electrical appliance), V (circuit breaker), C (load switch), etc

Operating conditions

1. Ambient Temperature: No more than +45℃, No less than -45°℃ . Average temperature no more than +35℃ within 24 hours.

2. Altitude: No more than 3000m.

3. Relative Humidity: the average daily value is no more than 95%, the average monthly value is no more than 90%.

4. Earthquake Intensity: No more than 8 degrees.

5. Vapor Pressure: the average daily value is no more than 2.2kPa,and the average monthly value is no more than 1.8kPa.

6. Installation locations without fire, explosion danger, serious pollution, chemical corrosion and violent vibration.

Technical data

Item Unit C Module F Module V Module
Load switch Load switch with fuse Vacuum switch Disconnector/  Earthing Switch
Rated voltage kV 12 12 12 12
Rated frequency1min Hz 50/60 50/60 50/60 50/60
Power frequency withstand voltage in 1 min kV 42/48 42/48 42/48 42/48
Lightning impulse withstand voltage(Peak) kV 75/85 75/85 75/85 75/85
Rated current A 630 note1) 630 /
Rated closed loop breaking current A 630 / / /
Rated cable charging breaking current A 10 / / /
Rated short circuit making current A 50 80 50 50
Rated peak withstand current kA 50 / 50 /
Rated short time withstand current kA/3S 20 / 20 /
Rated short circuit breaking current kA / 31.5 20 /
Rated transfer current A / 1700 / /
Max. rated current of fuse A / 125 / /
Loop resistance μΩ ≤200 ≤500 / /
Mechanical life times 5000 3000 5000 2000

Feature

1. YVG-12 switchgear mainly has three functional units, namely V unit (circuit breaker unit), C unit (load switch unit), F unit  (combined electrical unit), when the system requires multiple units to be configured , can be arbitrarily expanded on the left and right sides, and can be arranged arbitrarily according to different design schemes toachieve different configuration requirements.

2. Each unit is structurally divided into three parts: instrument room,operating mechanism and primary circuit. The instrument room can be equipped with microcomputer protection (intelligent controller) and other meters. The operating mechanism is a special spring operation mechanism,which can also be equipped with additional Electric operating mechanism;the primary circuit adopts APG automatic gel technology, and the bus bar, isolating switch and arc extinguishing chamber are completely sealed in epoxy resin, and there are special joints connected to the bus bar.

3. YVG-12 solid insulation switchgear has the advantages of compact structure, full insulation, long life, maintenance-free,  small space occupation, safety and reliability, and is not affected by the working environment. It is widely used in industrial and civil ring network andterminal power supply .

Design scheme

Reliable interlocking solid insulated ring main unit (RMU)

Overall and mounting dimensions(mm)

Reliable interlocking solid insulated ring main unit (RMU)

Reliable interlocking solid insulated ring main unit (RMU)

Reliable interlocking solid insulated ring main unit (RMU)

Reliable interlocking solid insulated ring main unit (RMU)

Reliable interlocking solid insulated ring main unit (RMU)

Demande
+86
Cliquer pour téléverser un fichier
Télécharger
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Télécharger
Obtenir l'application commerciale IEE-Business
Utilisez l'application IEE-Business pour trouver du matériel obtenir des solutions se connecter avec des experts et participer à la collaboration sectorielle en tout lieu et à tout moment soutenant pleinement le développement de vos projets et activités dans le secteur de l'énergie
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO