| Brand | ROCKWILL |
| Model NO. | 252kV 363 kV HV SF6 Circuit Breaker |
| Rated voltage | 252kV |
| Rated normal current | 4000A |
| Series | LW10B |
Description
SF6 circuit-breaker, the circuit-breaker adopts SF6 gas as insulation and arc extinguishing medium, and its arc extinguishing chamber is a single voltage variable opening distance, which is mainly used to meet the rated current and fault current, convert the line, and realize the control and protection of the transmission line. It is equipped with a spring energy storage hydraulic operating mechanism for opening, closing and automatic reclosing. The circuit breaker is divided into two kinds of products: break without closing resistance and break with closing resistance.
Main Features
The arc extinguishing chamber structure design of the circuit breaker is reasonable, the breaking ability is strong, the contact electric life is long (rated short circuit breaking up to 20 times), and the maintenance interval is long.
The mechanical reliability of the product is good, to ensure the mechanical life of 5,000 times.
The circuit breaker operation noise is low.
The new hydraulic operating mechanism has no exposed pipeline, reducing the oil leakage link.
Technical parameter

The LW10B \ lLW36 \ LW58 series products in the sample booklet are porcelain column SF ₆ circuit breakers based on the ABB'LTB series improvement, with voltage coverage of 72.5kV-800kV, using Auto Buffer ™ Self powered arc extinguishing technology or vacuum arc extinguishing technology, integrated spring/motor driven operating mechanism, supports various customized services, covering 40.5-1100kV full voltage levels, with outstanding modular design and strong customization ability, suitable for projects that require flexible adaptation to different power grid architectures. Made in China, with fast global service response speed, high logistics efficiency, and high reliability at a reasonable price.
live tank circuit breaker is a structural form of high-voltage circuit breaker, which is characterized by the use of ceramic insulation pillars to support key components such as arc extinguishing chamber and operating mechanism. The arc extinguishing chamber is usually arranged on the top or pillar of the ceramic pillar. It is mainly suitable for medium and high voltage power systems, with voltage levels covering the range of 72.5 kV to 1100 kV. live tank circuit breakers are common control and protection equipment in outdoor distribution devices such as 110 kV, 220 kV, 550 kV, and 800 kV substations.