Outdoor SF6 Insulated RMU - RMR 10kV 15kV 24kV 35kV

  • Outdoor SF6 Insulated RMU - RMR 10kV 15kV 24kV 35kV
Key attributes
Brand ROCKWILL
Model NO. Outdoor SF6 Insulated RMU - RMR 10kV 15kV 24kV 35kV
Rated voltage 24kV
Rated normal current 630A
Series RMR
Product descriptions from the supplier
Description

Product Description

Outdoor SF6 Insulated RMU - RMR 12kV/24kV/35kV(GIS)
 
The SF6 insulated switchgear is suitable for middle voltage power distribution system with a rated voltage of 12kV. It could be used as RMUs in a power supply network, fault isolating switches and sectionalizing switches. If equipped with distribution automation devices (FTU/DTU) and communication devices, the SF6 insulated switchgear could communicate with the control center, measure the cable voltage, current, etc, and monitor the working status of switches.
 
RMR- 40.5 series of ring main unit is SF6 gas-insulated metal common tank enclosed switchgear, consisting of load break switch unit, load break switch fuse combination electrical unit, vacuum circuit breaker unit, and the incoming line unit of bus. It adopts a range of advanced technologies and materials, with excellent electrical and mechanical properties, less affected by environment and climate, in smallsize, easy to install easy to operate, with no need of maintenance, and can be flexibly combined. Its clear and intuitive design ensures simple and direct operation, the feeder's connection capacity is large, suitable for a variety of wiring systems.
 
Besides,we can replace the SF6 gas with nitrogen(N2 gas) that it will become a environment protection green gas insulated switchgear. The green gas insulated switchgear safer and environmentally friendly more than SF6 GIS and it will replacing SF6 GIS in the future.
Features of Outdoor SF6 Insulated RMU
  • The SF6 is the insulation material which is sealed in a stainless-steel enclosure, fully-insulated and maintenance-free.
  • Long life endurance.
  • Obvious watchable open contacts.
  • Reliable interlock and safer operation.
Service Environment of Outdoor SF6 Insulated RMU
a) Air temperature:Maximum temperature: +40°C; Minimum temperature:-25°C
b) Humidity:Monthly average humidity 95%; Daily average humidity 90% .
c) Altitude above sea level: Maximum installation altitude: 2500m
d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
e) No frequent violent shake.
Technical Parameters
NO. Item Unit Data (11kV) Data (24kV) Data (33kV)
1 Rated Voltage kV 11 24 33
2 Rated Current A 630 630 630
3 Rated Short-Time Withstand Current kA (3s) 20 25 25
4 Dynamic Stable Current kA (0.3s) 50 50 50
5 Thermal Stable Current kA (3s) 20 20 20
6 Power Frequency Withstand Voltage (1min) kV 38 50 70
7 Lightning Impulse Withstand Voltage kV 75 125/145 170
8 Partial Discharge Test  
 
<9 kV <15 kV <45 kV
Discharge amount ≤10 pC Discharge amount ≤10 pC Discharge amount ≤10 pC
9 Enclosure Protection Class   IP55 IP55 IP55
Send inquiry
+86
Click to upload file
Download
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO