20kV-630A Outdoor Air/Sf6 Gas Insulation Ring Main Unit

  • 20kV-630A Outdoor Air/Sf6 Gas Insulation Ring Main Unit
Atributos-chave
Marca ROCKWILL
Número do Modelo 20kV-630A Outdoor Air/Sf6 Gas Insulation Ring Main Unit
Tensão nominal 24kV
Corrente nominal 630A
Frequência nominal 50/60Hz
Série RMR
Descrições de produtos do fornecedor
Descrição

Description

The complete variety, novel design, and excellent quality of our 3 phase dry power transformer, high voltage electrical switchgear, electrical distribution transformer have impressed our customers both at home and abroad. Insisting on the high quality generation line management and customers expert assistance, we now have designed our resolution to offer our buyers using the to start with amount getting and just after services practical experience. We are well aware that quality and service are the foundation of a company's survival, thus we will continue to uphold customer first and pursue excellence. They are sturdy modeling and promoting effectively all over the world.

Outdoor SF6 Ring Main Unit

RMR is the ring main unit for the asecondary distribution network. RMR can provide 10 different configurations, suitable for most switching applications in 12/24 kV distribution networks. It is scalable and combined with ABB's flexible modular and compact switchgear SafePlus concept, it is a complete solution for 12/24 kV secondary distribution networks. RMR and SafePlus have the same user interface. RMR is a completely sealed system with a stainless steel tank containing all live parts and switching functions. Sealed steel tanks with constant atmospheric conditions ensure a high degree of reliability as well as personnel safety and almost maintenance-free systems. The RMR concept provides a choice of switch fuse combinations or circuit breakers with relays to protect the transformer. RMR can provide an integrated remote control and monitoring unit. This product complies with the standards of IEC60420, GB/T11022, GB3804, GB3906

Outdoor SF6 ring main unit use environment:

a) Air temperature: highest temperature: +40℃; lowest temperature: -20℃

b) Humidity: monthly average humidity 95%; daily average humidity 90%.

c) Altitude: Maximum installation height: 2500m

d) Obviously there is no ambient air polluted by corrosive and combustible gases, steam, etc.

Technical data

No.

Item

Unit

C Module

V Module

Load break switch

Circuit breaker

1

Rated voltage

kV

12

24

12

24

2

Rated current

A

630

3

Rated frequency

Hz

50/60

4

1min Power frequency withstand voltage

kV

45

55

45

55

5

Lightning impulse withstand voltage

kV

75

125/150

75

125/150

6

Rated transfer current

A

1700

1400

 

7

Rated active load and close circuit breaking current

A

630

8

Rated cable charge breaking current

A

50&10

9

Rated short circuit breaking current

kA

 

20

16

10

Rated short circuit making current(peak)

kA

63

50

63

50

11

Short time (2s) withstand current, load switch/earth

kA

25/20

20/20

25/20

20/20

12

Rated withstand current (peak)

kA

63

50

63

50

13

Mechanism life

Times

3000

10000

3000

14

Dimension ( per unit)

mm

370x750x1345

Product Photos

 

20kv-630A Outdoor Air/Sf6 Gas Insulation Switchgear Ring Main Unit

Enviar consulta
+86
Clique para fazer upload do arquivo
Baixar
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Baixar
Obter Aplicativo Comercial IEE-Business
Use o aplicativo IEE-Business para encontrar equipamentos obter soluções conectar-se com especialistas e participar da colaboração setorial em qualquer lugar e a qualquer hora apoiando totalmente o desenvolvimento de seus projetos e negócios no setor de energia
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO