Solid Insulation Lbs Load Break Switch with Vacuum Interrupter 12/24kV 630A

  • Solid Insulation Lbs Load Break Switch with Vacuum Interrupter 12/24kV 630A
Attributs clés
Marque ROCKWILL
Numéro de modèle Solid Insulation Lbs Load Break Switch with Vacuum Interrupter 12/24kV 630A
tension nominale 24kV
courant nominal 630A
Série RMR
Descriptions de produits du fournisseur
Description

Main Technical Parameters

Rated voltage 12kV/24kV
Rated current 630/1250A
Rated frequency 50Hz
Rated short-term power frequencywithstand voltage dry test 48kV Between phases, phase to earth 42kV,Acrossthe interrupter,across isolatingdistance:48 kV
Rated lightning impulse with stand voltage 85 kV Between phases, phase to earth 75 kVA cross the interrupter, across isolatingdistance:85 kV
Short-time withstand current 25kA
Duration of short-circuit 4S
Peak withstand current 63kA
Short-circuit making current 63kA
Short-circuit breaking current  
AC component 25kA
DC component 51%
DC time constant 45 ms
Mechanical endurance Circuit-breaker:10000 times, Class M2. Disconnector: 3000times. class Ml: Earthing position: 3000 times, ClassM1

Use Of Condition

  • Ambient air temperature: from -5ºC to +40ºC, and average temperature shall be not higher than +35ºC in 24h.
  • Atmospheric conditions, relative humidity shall not be over 50% when the highest temperature is at +40ºC. Bu higher humidity is allowed when the temperature is lower, for instance, humidity can be 90% when +20ºC. It shall be taker into consideration that changes in temperature can accidentally cause condensation.
  • Absolute elevation shall be not higher than 2000m. (Otherwise, the capacity shall be reduced)
  • The temperatures for transportation and storage of this device is from +25ºC to +55ºCC, in a short time (no longer than 24h) the limiting temperature can reach +70ºC, in that case, unrecoverable damages will not occur on the device In case the above service conditions are not satisfied. the user shall consult with the manufacturer
  • If this device is used in offshore oil platforms or nuclear stations, another technical agreement shall be signed.

Product Size

Solid Insulation Lbs Load Break Switch with Vacuum Interrupter 12/24kV 630A

Site Working Photos

Solid Insulation Lbs Load Break Switch with Vacuum Interrupter 12/24kV 630A

Demande
+86
Cliquer pour téléverser un fichier
Télécharger
Experts Electrical is dedicated to serving the personnel in the global power industry.
Join Experts Electrical, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!
App Store
Télécharger
Obtenir l'application commerciale IEE-Business
Utilisez l'application IEE-Business pour trouver du matériel obtenir des solutions se connecter avec des experts et participer à la collaboration sectorielle en tout lieu et à tout moment soutenant pleinement le développement de vos projets et activités dans le secteur de l'énergie
Email
E-mail
WhatsApp
WhatsApp
Chat
Chen/CEO